MODEL 6502 ACTIVE LOOP ANTENNA Mounting
© EMC TEST SYSTEMS, L.P. SEPTEMBER 2002 3
REV E PN 399058
MOUNTING
The Model 6502 is fitted with a mounting bracket threaded to
accept a tripod mount with standard 1/4 “ x 20 threads. To mount
the loop antenna, thread a ¼” x 20 mounting knob or fixture into
the base of the mounting bracket. Take care not to cross thread this
connection as permanent damage to the antenna mount could
occur.
OPERATION
SATURATION INDICATOR
This LED illuminates when input signal intensity exceeds the 1 dB
compression level of 5 volts per meter and stays on for about 1
second afterward.
POWER INDICATOR
This LED illuminates to show that the loop is “on” and functional.
When the charge on the battery has decreased to the point the
antenna calibration is no longer valid, the LED extinguishes. Note:
The antenna is still functioning and will provide reasonable output
signals until the batteries are exhausted.
USE OF CALIBRATION DATA
In order to calculate the field strength you must add the signal level
+ cable loss + antenna factor. The sum equals the relative field
strength. Cable loss should be measured periodically for each cable
used in testing.