Model 4340 Digital Camera System (CCTV) User Manual
10 | Introduction Optional Configurations and Additional Components Following are the optional configurations for the Model 4340 CCTV, includi
Introduction | 11 IF YOU HAVE A MULTI-CAMERA SYSTEM For use with or without a shielded control room. You need these additional components: Th
12 | Introduction Power Supply Options The 10/100 Ethernet filter provides the power for all configurations except the tripod mount, which is
Introduction | 13 H-491009 Tripod The H-491009 tripod includes a 1/4–20 thread center pole and a 3/8-inch thread center pole. Use the 3/8-inch
14 | Introduction INSTALLATION AND SETUP CHECKLIST Complete pre-installation tasks—See page 23. Install the 10/100 Ethernet filter—See p
Maintenance | 15 2.0 Maintenance Before performing any maintenance, follow the safety information in the ETS-Lindgren Product Information Bu
16 | Maintenance Replacement and Optional Parts ETS-Lindgren may substitute a similar part or new part number with the same functionality for
Maintenance | 17 Part Description Part Number DCCTV System, Tripod Configuration, for use with or without shielded control room—Does not includ
18 | Maintenance This page intentionally left blank.
Specifications | 19 3.0 Specifications Camera Enclosure, Converter Enclosure, Dome The converter enclosure is included only with a tripod co
ii | ETS-Lindgren Inc. reserves the right to make changes to any product described herein in order to improve function, design, or for any other reas
20 | Specifications Battery Pack and Charger The battery pack and charger are included only with a tripod configuration. Battery Pack Dimensi
Specifications | 21 Panasonic Network Camera WV-SC385 For a complete list of camera specifications, see the separate Panasonic camera manual.
22 | Specifications Operating Temperature: 14°F to 122°F (–10°C to 50°C) Physical Dimensions: Height: 155 mm (6.09 in) Diameter: 115 mm
Pre-Installation Tasks | 23 4.0 Pre-Installation Tasks Before installing any components, follow the safety information in the ETS-Lindgren P
24 | Pre-Installation Tasks Choose the Camera Location You will install the 10/100 Ethernet filter on the outside of the chamber at the source
Install the 10/100 Ethernet Filter | 25 5.0 Install the 10/100 Ethernet Filter Before installing any components, follow the safety informati
26 | Install the 10/100 Ethernet Filter Overview of 10/100 Ethernet Filter Connections Overview of 10/100 Ethernet Filter Operation Followin
Install the 10/100 Ethernet Filter | 27 2. Clean DC power emerges from the filter module to the clean side of the 10/100 Ethernet filter as tw
28 | Install the 10/100 Ethernet Filter 2. Turn the top of the strain relief until the strain relief is loosened from the power cord. 3. Re
Wall or Ceiling Mount the Camera | 29 6.0 Wall or Ceiling Mount the Camera Before installing any components, follow the safety information i
| iii Table of Contents Notes, Cautions, and Warnings ... v 1.0 Introduction ...
30 | Wall or Ceiling Mount the Camera 3. Connect the assembled pipe to the filter penetration with a pipe-to-pipe coupler, running the cabl
Wall or Ceiling Mount the Camera | 31 If mounting the camera from the ceiling, connect the camera penetration to the pipe with a pipe-to-pipe c
32 | Wall or Ceiling Mount the Camera 6. Plug the Ethernet cable from the camera into the connector on the Ethernet-to-fiber optic converte
Install Optional Components | 33 7.0 Install Optional Components Before installing any components, follow the safety information in the ETS-
34 | Install Optional Components
Install Optional Components | 35 CHAMBER WITH SHIELDED CONTROL ROOM—ADDITIONAL PRE-INSTALLATION TASKS Install the fiber optic feedthrough conne
36 | Install Optional Components Your 10/100 Ethernet filter may have shipped with an external fiber optic-to-Ethernet converter, and the fib
Install Optional Components | 37 If You Have a Tripod Mount (For Use with or without Shielded Control Room) A tripod mount configuration requir
38 | Install Optional Components
Install Optional Components | 39 TRIPOD MOUNT—ADDITIONAL PRE-INSTALLATION TASKS Install the fiber optic feedthrough connectors in the wall of t
iv | Chamber With Shielded Control Room—Additional Pre-installation Tasks ...
40 | Install Optional Components While performing the following steps, always protect and support the camera and camera enclosure. Do not rol
Install Optional Components | 41 3. Place the camera and camera enclosure in a stable location to prevent it from rolling or falling. Securely
42 | Install Optional Components If You Have a Multi-Camera System (For Use with or without Shielded Control Room) In addition to mounting the
Install Optional Components | 43
44 | Install Optional Components If you have a shielded control room, also install a 10/100 network switch, one fiber optic-to-Ethernet conver
Install Optional Components | 45 MULTI-CAMERA SYSTEM—ADDITIONAL PRE-INSTALLATION TASKS For a multi-camera configuration, you will need to insta
46 | Install Optional Components 3. If you do not have a shielded control room— Plug one Ethernet cable for each camera into any of the nu
Computer Setup | 47 8.0 Computer Setup Before connecting any components, follow the safety information in the ETS-Lindgren Product Informati
48 | Computer Setup 3. Follow the computer instructions to turn on the computer. 4. Internet Explorer automatically loads, links to the IP a
Operation | 49 9.0 Operation Before connecting any components, follow the safety information in the ETS-Lindgren Product Information Bulleti
| v Notes, Cautions, and Warnings Note: Denotes helpful information intended to provide tips for better use of the product. Caution: Denotes a haza
50 | Operation Viewing Images from the Camera When the camera is powered on, it will take up to one minute to start up. To view an image from
Operation | 51 ARRANGING MULTI-CAMERA IMAGES 1. Power up all cameras. Allow cameras to complete self-test routine. 2. Open Internet Explorer
52 | Operation 4. Enter the title of the camera, using a maximum of 20 characters. The camera title will display on the multi-screen. Do not
Operation | 53 Operating the Battery Pack You must charge the battery pack before using it for the first time. See Charging the Battery Pack o
54 | Operation Turn off the battery pack before connecting or disconnecting cables. (For operation) To turn the battery pack on—Push the pow
Operation | 55 STORING THE BATTERY PACK Make sure the power button is in the off position before storing the battery pack. Fully charge the ba
56 | Operation CHARGING THE BATTERY PACK You must charge the battery pack before using it for the first time. You may charge the battery pac
Operation | 57 4. Slide the selector switch on the battery charger to 1.8A. 5. Connect the battery charger to a mains supply (100 or 240 VA
58 | Operation REPLACING THE BATTERY PACK At end of useful life, please recycle the used batteries, or dispose of them safely and properly. M
Operation | 59 4. Inside the enclosure, disconnect the two charging cables by separating each cable at the middle connector.
vi | This page intentionally left blank.
60 | Operation 5. Place the enclosure on one side, and remove the two bracket screws from the bottom of the enclosure. To prevent the batter
Operation | 61 7. Lift to remove the battery pack from the enclosure. 8. Place the new battery pack inside the enclosure. 9. Repla
62 | Operation This page intentionally left blank.
Warranty | 63 Appendix A: Warranty See the Product Information Bulletin included with your shipment for the complete ETS-Lindgren warranty fo
64 | Warranty This page intentionally left blank.
EC Declaration of Conformity | 65 Appendix B: EC Declaration of Conformity The EC Declaration of Conformity is the method by which ETS-Lindgre
Introduction | 7 1.0 Introduction The ETS-Lindgren Model 4340 Digital Camera System (CCTV) is designed to monitor tests conducted in anechoic
8 | Introduction
Introduction | 9 The standard configuration for the Model 4340 CCTV includes these components: Panasonic Network Camera WV-SC385—Includes Et
Comments to this Manuals